Main Article Content

Mulidini
Asri Yuniar Dwi Nanda
Nissa Khalida Hanum
Lina Nurfadhila
Marsah Rahmawati Utami

Page: 741-749

Abstract

Analytical method validation is a process that ensures accurate, specific, reproducible and stable analysis of the analytical range appropriate to the intended use. Analytical method validation include all procedur for that demonstrate quantitative measure of analytes such as from plasma. Determination of the concentration of a drug in plasma is complex because plasma is a complex matrix. The drug identified was metformin. Metformin is a drug orally antihyperglycemic agent used in the management of type II diabetes mellitus. Methods for quantitation of metformin in human plasma or in pharmaceutical form, one of which uses High Performance Liquid Chromatography (HPLC). HPLC is a liquid chromatography technique used to process various mixture components. This article review aims to make it easier for readers and future researchers to determine the presence of metformin in human plasma by using the HPLC analysis method accurately. This research method uses the literature review method using national journals and international journals through the google scholar database. Methods by KCKT or HPLC that can be used to validate the determination of metformin levels in plasma include RP-HPLC, HPLC, HPLC-UV, and U-HPLC. The most commonly used method with the best validity, efficiency and time estimation is RP-HPLC..

Downloads

Download data is not yet available.

Article Details

How to Cite
Mulidini, M., Nanda , A. Y. D., Hanum, N. K., Nurfadhila , L., & Utami, M. R. (2023). Analysis and Validation of Metformin in Human Plasma Using the HPLC Method. Journal of Pharmaceutical and Sciences, 6(2), 741–749. https://doi.org/10.36490/journal-jps.com.v6i2.141
Section
Review Article

References

Abdessadek, M., Tadmori, A. E., Ahmed, E. A., Diarra, M., Magoul, R., Ajdi, F., & Khabbal, Y. (2015). Simple HPLC-UV Method For Determination Of Metformin In Human Plasma And Erythrocytes Application To Therapeutic Drug Monitoring. International Journal Of Pharmacy And Pharmaceutical Sciences, 35-39.

Alshishani, A., Makahleh, A., Yap, H. F., Gubartallah, E. A., Salhimi, S. M., & Saad, B. (2016). Ion-Pair Vortex Assisted Liquid-Liquid Microextraction With Back Extraction Coupled With High Performance Liquid Chromatography-UV For The Determination Of Metformin In Plasma. Talanta, 161, 398-404.

Annissa, S., Musfiroh, I., & Indriati, L. (2020). Perbandingan Metode Analisis Instrumen HPLC dan UHPLC. Article Review, Farmaka, 17(3), 189-196.

Ashutosh, K. S., Manidipa, D., Seshagiri, R. J. V. L. N., & Gowri, S. D. (2015). New Validated Stability Indicating RP-HPLC Method For Simultaneous Estimation Of Metformin And Alogliptin In Human Plasma. J Chromatogr Sep Tech, 6(6), 1-6.

Balamurugan, K., Mishra, K., & Suresh, R. 2018. Optimization and Validation of the Simultaneous Determination of Vildagliptin and Metformin, in Bulk and Formulation by A Reverse Phase HPLC Method Using D-Optimal Experimental Design. Journal of Pharmaceutical and Scientific Innovation, 12 (8), 1-12.

Brocks, D., Gabr, R. Q., & Padwal, R. S. (2010). Determination Of Metformin In Human Plasma And Urine By High-Performance Liquid Chromatography Using Small Sample Volume And Conventional Octadecyl Silane Column. Journal Of Pharmacy & Pharmaceutical Sciences, 13(4), 486-494.

Chhetri, H. P., Thapa, P., & Van Schepdael, A. (2014). Simple HPLC-UV Method For The Quantification Of Metformin In Human Plasma With One Step Protein Precipitation. Saudi Pharmaceutical Journal, 22(5), 483-487.

Fauziah, F., Kardela, W., Rasyid, R., & Silvi, M. (2017). Validasi Metode Analisis Α-Mangostin Dalam Plasma Darah Manusia Secara In Vitro Dengan Kromatografi Lapis Tipis-Densitometri. Jurnal Farmasi Higea, 9(2), 96-102.

Fransiska, A. N., Masyrofah, D., Putri, G. K., Malik, L. H., Wulan Birru, P., & Putri, T. R. (2022). Analisis Senyawa Obat dalam Sampel Biologis Plasma Darah. Syntax Idea, 4(5), 905-912.

Hasanah, A. N. (2016). Optimasi Kondisi Pemisahan Glibenklamid Kombinasi Metformin Dengan KCKT-SPE MIP Akrilamid. Indonesian Journal Of Pharmaceutical Science And Technology, 3(2), 38-46.

Kang, Y. J., Jeong, H. C., Kim, T. E., & Shin, K. H. (2020). Bioanalytical Method Using Ultra-High-Performance Liquid Chromatography Coupled With High-Resolution Mass Spectrometry (UHPL-CHRMS) For The Detection Of Metformin In Human Plasma. Molecules, 25(20), 4625.

Lestari, S. W. (2014). Validasi Metode Penetapan Kadar Aliskiren dalam Plasma Darah secara In Vitro menggunakan Kromatografi Cair Kinerja Tinggi (KCKT).

Magdy, G., Al-Enna, A. A., Belal, F., El-Domany, R. A., & Abdel-Megied, A. M. (2023). Analytical Quality-By-Design Approach For Development And Validation Of HPLC Method For The Simultaneous Estimation Of Omarigliptin, Metformin, And Ezetimibe: Application To Human Plasma And Dosage Forms. BMC Chemistry, 17(1), 1-10.

Nikam, N., Maru, A., Jadhav, A., & Malpure, P. (2019). Analytical Method Development and Validation of Metformin Hydrochloride by using RP HPLC with ICH Guidelines. International Journal of Trend in Scientific Research and Development, 3(3), 415-419.

Pandya, R. H., Rathod, R., & Maheswari, D. G. (2014). Bioanalytical Method Development And Validation For Simultaneous Determination Of Linagliptin And Metformin Drugs In Human Plasma By RP-HPLC Method. Pharmacophore, 5(2), 202-218.

Patra, R., Kollati, Y., NS, S. K., & Dirisala, V. R. (2021). Valsartan In Combination With Metformin And Gliclazide In Diabetic Rat Model Using Developed RP-HPLC Method. Future Journal Of Pharmaceutical Sciences, 7, 1-10.

Porwal, P. K., & Talele, G. S. (2017). Development of validated HPLC-UV method for simultaneous determination of metformin, amlodipine, glibenclamide and atorvastatin in human plasma and application to protein binding studies. Bulletin of Faculty of Pharmacy, Cairo University, 55(1), 129-139.

Prasad, P. B. N., Satyanaryana, K., & Krishnamohan, G. (2015). Development And Validation Of A Method For Simultaneous Determination Of Metformin And Saxagliptin In A Formulation By RP-HPLC. American Journal Of Analytical Chemistry, 6(11), 841.

Rohayati, A., Hasanah, A. N., Saptarini, N. M., & Aryanti, A. D. (2015). Optimasi Kondisi Pemisahan Glibenklamid Kombinasi Metformin Dalam Plasma Darah Menggunakan KCKT. Indonesian Journal Of Pharmaceutical Science And Technology, 2(3), 96.

Sebaiy, M. M., El-Adl, S. M., Baraka, M. M., & Hassan, A. A. (2020). Rapid RP-HPLC Method For Simultaneous Estimation Of Metformin, Pioglitazone, And Glimepiride In Human Plasma. Acta Chromatographica, 32(1), 16-21.

Shakoor, A., Ahmed, M., Ikram, R., Hussain, S., Tahir, A., Jan, B. M., & Adnan, A. (2020). Stability-Indicating RP-HPLC Method For Simultaneous Determination Of Metformin Hydrochloride And Vildagliptin In Tablet And Biological Samples. Acta Chromatographica, 32(1), 39-43.

Sholikhah, A. I. (2019). Gambaran Pola Penggunaan Metformin Terhadap Kadar Kreatinin Serum Pada Pasien Diabetes Melitus Tipe 2 Di Rumah Sakit" X". Social Clinical Pharmacy Indonesia Journal, 4(2), 66-74.

Troja, E., Deda, L., & Boçari, G. (2015). Ion-Pair HPLC Method For The Quantification Of Metformin In Human Plasma And Its Application To A Pharmacokinetic Study. Methodology.

Yusuf, A., Alvi, S. N., & Hammami, M. M. (2015). Development and validation of RP-HPLC method for the determination of metformin in human plasma. WJPPS, 4(7), 128-38.

Most read articles by the same author(s)

<< < 1 2