Abstract
Amlodipine has a high bioavailability, a large volume of distribution, and a sufficiently long elimination half-life of 35 to 50 hours so that low plasma concentrations of amlodipine are achieved after oral administration. One of the methods used to quantify amlodipine levels is High-Performance Liquid Chromatography and Liquid Chromatography Mass Spectrometry. This review aims to compare the validation of the two methods according to the parameters and determine the advantages and disadvantages of each process in terms of accuracy in identifying samples of amlodipine in blood plasma. An article review was conducted by collecting data from 2013 to 2023 using the Google Scholar and ScienceDirect databases filtered according to the inclusion and exclusion criteria. Seven journals could be compared according to the parameters of precision, accuracy, linearity, limit of detection and quantification. Better precision and accuracy are in the High-Performance Liquid Chromatography method, and good linearity is in the Mass Spectrometry Liquid Chromatography method. Liquid Chromatography Method Mass Spectrometry is easier to detect amlodipine levels because it can detect concentrations of more minor sample levels.
Downloads
Article Details

This work is licensed under a Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International License.
References
Ahuja, S., dan Dong, M, W, Eds. (2005). Handbook of Pharmaceutical Analysis by HPLC, Edisi Pertama. Elsevier, Inc: United Kingdom
Alawiyah, A., Mutakin. (2017). Analisis Amlodipin Dalam Plasma Darah dan Sediaan Farmasi. Farmaka, 15(3), 123-133
Angraini, N., Desmaniar, P. (2020). Optimasi High Performance Liquid Chromatography (HPLC) Untuk Analisis Asam Askorbat Guna Menunjang Kegiatan Praktikum Bioteknologi Kelautan. Jurnal Penelitian Sains, 22(2), 69-75.
AOAC. (2019). Official Methods of Analysis of The Association of Analytical Chemists. Association of Official Analytical Chemists, Inc. Virginia USA.
Bhatt, B., S.S. Agrawal. (2007). Capsules: Pharmaceutical Technology. Delhi Institute of Pharmaceutical Science and Research Sector-3, Pushp Vihar, New Delhi, 2-3.
Chan-Mei., Chun-Min. W., Fan-Long. B., Rui. C., Xiao-Lu. W., Rong Li., Ben-Jie. W., Rui-Chen. (2013). Determination of Amlodipine in Human Plasma by LC-MS/MS and Its Bioequivalence Study in Healthy Chinese Subjects. Pharmacology & Pharmacy, 2013, 4, 191-200
Christian, C. M. (2014). The Development and Validation of a Visual-Spatial Chemistry Specific (VSCS) Assessment Tool‖. Journal of Research in Science Teaching. 51(8), 963–981.
Dyade, G. K., Lunkad, A. S., & Sawant R. L. Bio Analytical Validated Technique for the Simultaneous Estimation of Amlodipine, Rosuvastatin and Valsartanin Human Plasma by RP-HPLC Method. International Journal of Pharmaceutical Science and Research, 14(5), 2602-2612
Dio, R. G. R., Bahri, S., Kiswandono, A. A., & Supriyanto, R. (2021). Validasi Metode Fotodegradasi Congo Red Terkatalis Zno/Zeolit Y Secara Spektrofotometri Uv-Vis. Analytical and Environmental Chemistry, 6 (2), 134-144
Kim, H. M., Juh-Hwan, P., Nguyen, P. L., Dae-Duk K., Sung W. K. (2019). Simultaneous Determination of Cardiovascular Drug in Dried Blood Spot by Liquid Chromatography-tandem Mass Spectrometry. Journal of Food and Drug Analysis, 27, 906-914
Gupta R. K., Chaurasiab. A., Mishrac. K. B., Chaturvedid. V., Guptad. K. P. (2017). Estimation of Amlodipine in Human Plasma by Liquid Chromatography-Tandem Mass Spectrometry. MIT International Journal of Pharmaceutical Sciences, 3(2), 57–63
Haque, M. A., Priya, D. K. S., Mohanty, D., Bakshi V., Boggula, N. (2018). Analytical Method Development and Validation of Amlodipine in Human Plasma Using Liquid Chromatography-Mass Spectrometry/Mass Spectrometry. Asian Journal of Pharmaceutical and Clinical Research. 11(7), 393-397
Harmita. (2004). Petunjuk Pelaksanaan Validasi Metode dan Cara Perhitungannya. Majalah Ilmu Kefarmasian. Jakarta: FMIPA-UI Jakarta
ICH. (1995). Validation of Analytical Procedures: Text and Methodology. European Medicines Agency
Kemenkes RI. (2018). Hasil utama RISKESDAS 2018. Jakarta: Badan Penelitian dan Pengembangan Kesehatan Kementerian Kesehatan RI
Laboratorium Penelitian dan Pengujian Terpadu. (2022). Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS) [Newsletter]. Yogyakarta: Universitas Gadjah Mada LPPT
Shah, J. V., Parekh, J. M., Shah, P. A., Shah, P. V., Sanyal, M., & Shrivastav, P. S. (2017). Application of an LC-MS/MS Method for the Analysis of Amlodipine Valsartan and Hydrochlorothiazide in Polypill for Bioequivalence Study. Journal of Pharmaceutical Analysis. 7, 309-316
World Health Organization. (2023, 16 Maret). Hypertension [website]. Diperoleh dari https://who.int/news-room/fact-sheets/detail/hypertension
Yulia. (2010). Validasi Metode. Bandung: Diktat Validasi Metode Pusat Penelitian LIPI
Yuwono, M., Indrayanto, G. (2005). Validation of Chromatographic Methods of Analysis. Profile of Drug Substances, Excipients, and Related Methodology, 32, 243 – 259.