Main Article Content

Deborah Chennia Lau
Tiara Cinta Amelia
Diara Ravika Hadjami

Page: 1106-1112

Abstract

Amlodipine has a high bioavailability, a large volume of distribution, and a sufficiently long elimination half-life of 35 to 50 hours so that low plasma concentrations of amlodipine are achieved after oral administration. One of the methods used to quantify amlodipine levels is High-Performance Liquid Chromatography and Liquid Chromatography Mass Spectrometry. This review aims to compare the validation of the two methods according to the parameters and determine the advantages and disadvantages of each process in terms of accuracy in identifying samples of amlodipine in blood plasma. An article review was conducted by collecting data from 2013 to 2023 using the Google Scholar and ScienceDirect databases filtered according to the inclusion and exclusion criteria. Seven journals could be compared according to the parameters of precision, accuracy, linearity, limit of detection and quantification. Better precision and accuracy are in the High-Performance Liquid Chromatography method, and good linearity is in the Mass Spectrometry Liquid Chromatography method. Liquid Chromatography Method Mass Spectrometry is easier to detect amlodipine levels because it can detect concentrations of more minor sample levels.


 

Downloads

Download data is not yet available.

Article Details

How to Cite
Lau, D. C., Amelia, T. C., & Hadjami, D. R. (2023). Review: Comparison of Validation and Amlodipine Content in Blood Plasma Samples Using High Performance Liquid Chromatography and Liquid Chromatography Mass Spectrometry. Journal of Pharmaceutical and Sciences, 6(3), 1106–1112. https://doi.org/10.36490/journal-jps.com.v6i3.166
Section
Review Article

References

Ahuja, S., dan Dong, M, W, Eds. (2005). Handbook of Pharmaceutical Analysis by HPLC, Edisi Pertama. Elsevier, Inc: United Kingdom

Alawiyah, A., Mutakin. (2017). Analisis Amlodipin Dalam Plasma Darah dan Sediaan Farmasi. Farmaka, 15(3), 123-133

Angraini, N., Desmaniar, P. (2020). Optimasi High Performance Liquid Chromatography (HPLC) Untuk Analisis Asam Askorbat Guna Menunjang Kegiatan Praktikum Bioteknologi Kelautan. Jurnal Penelitian Sains, 22(2), 69-75.

AOAC. (2019). Official Methods of Analysis of The Association of Analytical Chemists. Association of Official Analytical Chemists, Inc. Virginia USA.

Bhatt, B., S.S. Agrawal. (2007). Capsules: Pharmaceutical Technology. Delhi Institute of Pharmaceutical Science and Research Sector-3, Pushp Vihar, New Delhi, 2-3.

Chan-Mei., Chun-Min. W., Fan-Long. B., Rui. C., Xiao-Lu. W., Rong Li., Ben-Jie. W., Rui-Chen. (2013). Determination of Amlodipine in Human Plasma by LC-MS/MS and Its Bioequivalence Study in Healthy Chinese Subjects. Pharmacology & Pharmacy, 2013, 4, 191-200

Christian, C. M. (2014). The Development and Validation of a Visual-Spatial Chemistry Specific (VSCS) Assessment Tool‖. Journal of Research in Science Teaching. 51(8), 963–981.

Dyade, G. K., Lunkad, A. S., & Sawant R. L. Bio Analytical Validated Technique for the Simultaneous Estimation of Amlodipine, Rosuvastatin and Valsartanin Human Plasma by RP-HPLC Method. International Journal of Pharmaceutical Science and Research, 14(5), 2602-2612

Dio, R. G. R., Bahri, S., Kiswandono, A. A., & Supriyanto, R. (2021). Validasi Metode Fotodegradasi Congo Red Terkatalis Zno/Zeolit Y Secara Spektrofotometri Uv-Vis. Analytical and Environmental Chemistry, 6 (2), 134-144

Kim, H. M., Juh-Hwan, P., Nguyen, P. L., Dae-Duk K., Sung W. K. (2019). Simultaneous Determination of Cardiovascular Drug in Dried Blood Spot by Liquid Chromatography-tandem Mass Spectrometry. Journal of Food and Drug Analysis, 27, 906-914

Gupta R. K., Chaurasiab. A., Mishrac. K. B., Chaturvedid. V., Guptad. K. P. (2017). Estimation of Amlodipine in Human Plasma by Liquid Chromatography-Tandem Mass Spectrometry. MIT International Journal of Pharmaceutical Sciences, 3(2), 57–63

Haque, M. A., Priya, D. K. S., Mohanty, D., Bakshi V., Boggula, N. (2018). Analytical Method Development and Validation of Amlodipine in Human Plasma Using Liquid Chromatography-Mass Spectrometry/Mass Spectrometry. Asian Journal of Pharmaceutical and Clinical Research. 11(7), 393-397

Harmita. (2004). Petunjuk Pelaksanaan Validasi Metode dan Cara Perhitungannya. Majalah Ilmu Kefarmasian. Jakarta: FMIPA-UI Jakarta

ICH. (1995). Validation of Analytical Procedures: Text and Methodology. European Medicines Agency

Kemenkes RI. (2018). Hasil utama RISKESDAS 2018. Jakarta: Badan Penelitian dan Pengembangan Kesehatan Kementerian Kesehatan RI

Laboratorium Penelitian dan Pengujian Terpadu. (2022). Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS) [Newsletter]. Yogyakarta: Universitas Gadjah Mada LPPT

Shah, J. V., Parekh, J. M., Shah, P. A., Shah, P. V., Sanyal, M., & Shrivastav, P. S. (2017). Application of an LC-MS/MS Method for the Analysis of Amlodipine Valsartan and Hydrochlorothiazide in Polypill for Bioequivalence Study. Journal of Pharmaceutical Analysis. 7, 309-316

World Health Organization. (2023, 16 Maret). Hypertension [website]. Diperoleh dari https://who.int/news-room/fact-sheets/detail/hypertension

Yulia. (2010). Validasi Metode. Bandung: Diktat Validasi Metode Pusat Penelitian LIPI

Yuwono, M., Indrayanto, G. (2005). Validation of Chromatographic Methods of Analysis. Profile of Drug Substances, Excipients, and Related Methodology, 32, 243 – 259.

Most read articles by the same author(s)